Sho-Rate™ Series Glass Tube Variable Area Flow Meters
Proven performance for low flow rates. Versatile options to match your needs.
Models 1250A / 1255A / 1350G / 1355G / 1358
Sho-Rate™ 1350 / 1355 / 1358 features include:
- Three accuracy levels: 3% (low-flow Model 1355), 5% (low-flow Model 1350) or standard accuracy of 10% (high-flow Model 1358)
- Repeatability of 0.25% Full Scale (0.5% Full Scale for Model 1358)
- Scale includes built-in magnifier – scale decals can be applied directly to the tube to support unique flow ranges and units of measure
- Options include standard or NRS™ integral needle control valves, as well as flow controllers on the inlet or outlet to go beyond measurement
Sho-Rate™ 1250 / 1255 features include:
- Two accuracy levels: 5% Full Scale (Model 1250), 10% Full Scale (Model 1255)
- Standard direct-read scales for common units and fluids – 65 mm, 150 mm scale lengths (approximate)
- Inlet valve and outlet valve with options of cartridge valve, precision control valve or no valve
- Easy-change design allows quick interchangeability of tube assemblies
- Rotating lens provides a 180° view with magnification
Benefits
- Options offer value-added features to meet project or OEM requirements
- Borosilicate glass is resistant to thermal shock and corrosive gases and fluids
- Corrosion-resistant material options for scales, floats, fittings and valves accommodate demanding applications
- Integral float stops prevent loss of float during tube removal
- Enhance accuracy with easy-to-read scales with magnification
Applications
- Pharmaceutical production
- Research
- Chemical manufacturing
- Analytical instrumentation
- Water treatment and distribution systems
Chúng tôi cung cấp đầy đủ các thiết bị từ hãng Brook Instrument:
| 100% USA Origin | Brooks Vietnam | SLA5860 Thermal Mass Flow Meter |
| Model Code : SLA5860SB1DA0B2A1 | ||
| SLA5860S Flow Meter, Body 0 | ||
| Digital I/O. Communications S Smart Emulation (Analog and/or RS485) | ||
| Mechanical Connections B1 1/4” Tube Compression w/Filter | ||
| O-ring Material D Kalrez | ||
| Valve Seat Material A None | ||
| Valve Type 0 None | ||
| Analog I/O B 0-5 VDC | ||
| Power Supply 2 +24 Vdc | ||
| Output Enhancement A Standard Setting / Response Time | ||
| Certification 1 Standard Location (Safe Area) | ||
| Customer Process | ||
| Fluid: 10% SO2, 5% Water vapor, 85% N2 (percentage in mass) | ||
| Normal Upstream Pressure: 60-150 psig | ||
| Normal Downstream Pressure: 0-110 psig | ||
| Operating temperature : 65 degC | ||
| Meter Specifications | ||
| Meter Flow (Full Scale): 3000 mlst/min | ||
| Reference Temp: 70 degF | ||
| Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) | ||
| Max Pressure Rating: 100 bar-g | ||
| Max Temperature: 65 °C | ||
| NOTE: Operating temp cannot exceed 65 degC | ||
| (MFM 1: 5860S/BC1GA0AACA1B1 | ||
| Request: Need to measure correctly (30 ml – 3000ml/min) for wet gas (10% wt SO2 + 5% steam +N2 balance). | ||
| Flow range: 0…3 ln/min for wet gas(10% wt SO2 + 5% steam +N2 balance) | ||
| Inlet pressure: max. 150 psig @ 70°C | ||
| max. 60 psig @ 35°C | ||
| Outlet pressure: 0…110 psig @ 70°C | ||
| 0 psig @ 35°C | ||
| Temperature: 35°C…70°C | ||
| Output signal: 0..5 Vdc with RS232 interface | ||
| Setpoint signal: 0…5 Vdc or 0..100% RS232 | ||
| Connections: 1/4” OD Compression type (male) | ||
| Seals: Kalrez 6375) | ||
| 100% USA Origin | Brooks Instrument Vietnam | Brooks SLA5860 Thermal Mass Flow Meter |
| Model Code : SLA5860SB1DA0B2A1 | ||
| SLA5860S Flow Meter, Body 0 | ||
| Digital I/O. Communications S Smart Emulation (Analog and/or RS485) | ||
| Mechanical Connections B1 1/4” Tube Compression w/Filter | ||
| O-ring Material D Kalrez | ||
| Valve Seat Material A None | ||
| Valve Type 0 None | ||
| Analog I/O B 0-5 VDC | ||
| Power Supply 2 +24 Vdc | ||
| Output Enhancement A Standard Setting / Response Time | ||
| Certification 1 Standard Location (Safe Area) | ||
| Customer Process | ||
| Fluid : 10% CH4O (methanol), 10% Water vapor, 30% CO2, 50% H2 (percentage in mass) | ||
| Normal Upstream Pressure : 1.5-10 bar-g | ||
| Operating temperature : 65 degC | ||
| Meter Specifications | ||
| Meter Flow (Full Scale) : 1000 mlst/min | ||
| Reference Temp : 70 degF | ||
| Accuracy : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) | ||
| Max Pressure Rating : 100 bar-g | ||
| Max Temperature : 65 °C | ||
| NOTE: 1) Operating temp cannot exceed 65 degC. | ||
| 2) Metal seals not available. | ||
| (MFM 2: 5860S/BC1GA0AACA1B1 | ||
| Flow: 20…1000 ml/min for wet gas (10% wt MeOH vapour +10% steam +30%CO2 50%H2). | ||
| Inlet pressure:. 1.5 barg….10 barg | ||
| Temperature: 35°C…80°C | ||
| Output signal: 0..5 Vdc with RS232 interface | ||
| Setpoint signal: 0…5 Vdc or 0..100% RS232 | ||
| Connections: 1/4” OD Compression type (male) | ||
| Seals: Metal) | ||
| 100% USA Origin | Brooks Vietnam | SLA5853 Thermal Mass Flow Controller |
| Model: SLA5853SZXXXX | ||
| Flow Meter, Body 3 | ||
| Digital I/O. Communications Smart Emulation (Analog and/or RS485) | ||
| Mechanical Connections 10mm Tube Compression | ||
| O-ring Material Viton | ||
| Valve Seat Material Viton | ||
| Valve Type Normally Closed (Press Diff > 2 bar) | ||
| Analog I/O 0-5 VDC | ||
| Power Supply +24 Vdc | ||
| Output Enhancement Standard Setting / Response Time | ||
| Certification Standard Location (Safe Area) | ||
| Customer Process | ||
| Fluid : Air | ||
| Normal Upstream Pressure : 7 bar-a | ||
| Normal Downstream Pressure : 1-5 bar-g | ||
| Meter Specifications | ||
| Meter Flow (Full Scale) : 400 ln/min | ||
| Reference Temp : 0 degC | ||
| Accuracy : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) | ||
| Max Pressure Rating : 70 bar-g | ||
| Max Temperature : 65 °C | ||
| Note: Spec reference to T88253/009. | ||
| (Mass flow contronllers and metters | ||
| BROOKS INSTRUMENT 6718WX - THE NETHERLANDS | ||
| SN/Year: T88253/009 2008 | ||
| Modelnumber: 5853SBZ1039 | ||
| I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA | ||
| OP - Press: pa = 7 Bar | ||
| Range/ fluid: 0 - 400 ln/min Air | ||
| DN 10 | ||
| Limit PS 70 barg@TS: 21 độ C PT 105 | ||
| barg@TS: 21 độ C) | ||
| 100% USA Origin | Brooks Instrument Vietnam | Brooks Model 2500 Series Flowmeters |
| Code: 2530A4A68SNVT | ||
| 2530 Acrylic Flowmeter | ||
| Revision A: Revision A | ||
| Tube Tube 4A68: 2-20 SCFM Air | ||
| Fittings S: Stainless Steel | ||
| Valve N: No Valve | ||
| Seals VT: Viton | ||
| 100% USA Origin | Brooks Vietnam | Brooks Oval Flowmeters |
| Replaced by: BM04 | ||
| Code: BM04ASSF2H1CKAA | ||
| (Brooks Oval Flowmeters, BM Oval Series, Models BM04 Through BM50 ® | ||
| Code: BM04ASSN2N1ARAA) | ||
| 100% USA Origin | Brooks Vietnam | SLAMF63 Thermal Mass Flow Meter |
| Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F | ||
| Digital I/O. Communications S: Smart Emulation (Analog and/or RS485) | ||
| Mechanical Connections 3A: DIN DN15 PN40 | ||
| O-ring Material B: Buna | ||
| Valve Seat Material A: None (Meter) | ||
| Valve Type 0: None | ||
| Analog I/O G: 4-20mA I/O (PG11 Cable Gland) | ||
| Power Supply 2: +24 Vdc | ||
| Output Enhancement A: Standard Setting / Response Time | ||
| Certification 1: Standard Location (Safe Area) | ||
| Valve Orifice Size: A No Orifice | ||
| Mass Flow Restrictor Type 5: LFE | ||
| Flow Restrictor Size D: Size D | ||
| Calibration conditions 1: Single S-series calibration | ||
| OEM Code A: Standard Brooks Label | ||
| Software Revision A: Revision A | ||
| Mounting Attitute 1: Horizontal base down | ||
| Baudrate F: 19200 | ||
| Customer Process: | ||
| Fluid: CO2 | ||
| Normal Upstream Pressure: 18 bar-g | ||
| Meter Specifications: | ||
| Meter Flow (Full Scale): 40 kg/hr | ||
| Reference Temp : 21.1 degC | ||
| Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) | ||
| Max Pressure Ratin: 70 bar-g | ||
| Max Temperature: 65 °C | ||
| Ingress Protection: IP66 | ||
| SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66 | ||
| Note: IP 66 tot hon IP65 | ||
| (SLA5863S3ABA0C2A1A5D1AA | ||
| IP65) | ||
| 100% USA Origin | Brooks Instrument Vietnam | Model Code: SLA5853S2CAB2B2A1 |
| SLA5853 Mass Flow Controller | ||
| Digital I/O, Communication S: Smart Emulation (analog or RS-485) | ||
| Mechanical Connection 2C: 3/8” Compression | ||
| O-ring material A: Viton | ||
| Valve Seat material B: Viton | ||
| Valve Type 2: Normally Close | ||
| Analog I/O B: 0-5 Volt | ||
| Power Supply 2: +24 Vdc | ||
| Output Enhancement A: Standard Setting / Response time | ||
| Certification 1: Standard Location | ||
| * Customer Process Data: | ||
| Fluid: Air | ||
| Upstream Pressure: 5-10 kg/cm2-g | ||
| Downstream Pressure: Customer to advice | ||
| * Meter Specifications: | ||
| Meter Range (Full Scale): 500 slpm | ||
| Ref Temperature: 70 degF | ||
| Accuracy: +/- 1% Rate | ||
| Max Pressure Rating: 100 bar g | ||
| Max Temperature: 65 °C | ||
| NOTE: Please confirm whether it is ln/min, lst/min or la/min that you need. | ||
| (Brooks Instrument mass flow controller for nitrogen and air. | ||
| - Flow rate: 0 - 500 lit/minute | ||
| - Compress air about 5 - 10 kg/cm2 | ||
| - I/O digital signal can controlled by computer. | ||
| - Material for flow meter is metal) | ||
| 100% USA Origin | Brooks Vietnam | SLAMF63 Thermal Mass Flow Meter |
| Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F | ||
| Digital I/O. Communications S: Smart Emulation (Analog and/or RS485) | ||
| Mechanical Connections 3A: DIN DN15 PN40 | ||
| O-ring Material B: Buna | ||
| Valve Seat Material A: None (Meter) | ||
| Valve Type 0: None | ||
| Analog I/O G: 4-20mA I/O (PG11 Cable Gland) | ||
| Power Supply 2: +24 Vdc | ||
| Output Enhancement A: Standard Setting / Response Time | ||
| Certification 1: Standard Location (Safe Area) | ||
| Valve Orifice Size: A No Orifice | ||
| Mass Flow Restrictor Type 5: LFE | ||
| Flow Restrictor Size D: Size D | ||
| Calibration conditions 1: Single S-series calibration | ||
| OEM Code A: Standard Brooks Label | ||
| Software Revision A: Revision A | ||
| Mounting Attitute 1: Horizontal base down | ||
| Baudrate F: 19200 | ||
| Customer Process: | ||
| Fluid: CO2 | ||
| Normal Upstream Pressure: 18 bar-g | ||
| Meter Specifications: | ||
| Meter Flow (Full Scale): 40 kg/hr | ||
| Reference Temp : 21.1 degC | ||
| Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) | ||
| Max Pressure Ratin: 70 bar-g | ||
| Max Temperature: 65 °C | ||
| Ingress Protection: IP66 | ||
| SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66 | ||
| Note: IP 66 tot hon IP65 | ||
| (SLA5863S3ABA0C2A1A5D1AA | ||
| IP65) | ||
| 100% USA Origin | Brooks Vietnam | 0254 Read Out & Control |
| Code: 0254AA2B23A | ||
| Type Housing: Panel Mount Kit | ||
| Power Cord For Power Supply: European Power Cord For 220 VAC | ||
| Power Supply Output Voltage: + 24 VDC | ||
| Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set | ||
| Options: RS-232 cable, 3 meter, 9 pin Female “D” | ||
| OEM Code: Standard Brooks Labelling | ||
| 100% USA Origin | Brooks Vietnam | 0254 Read Out & Control |
| Code: 0254AA2B23A | ||
| Type Housing: Panel Mount Kit | ||
| Power Cord For Power Supply: European Power Cord For 220 VAC | ||
| Power Supply Output Voltage: + 24 VDC | ||
| Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set | ||
| Options: RS-232 cable, 3 meter, 9 pin Female “D” | ||
| OEM Code: Standard Brooks Labelling | ||
| 100% USA Origin | Brooks Instrument Vietnam | Brooks SLA5863 Thermal Mass Flow Meter |
| Model: SLA5863S3ABA0C2A1A5D1AA | ||
| (Model: SLA5863S3A0C2A1A5D1AA | ||
| SN : F13319-001 | ||
| Gas : CO2 | ||
| Flow rate : 0-40kg/h) | ||
| 100% USA Origin | Brooks Instrument Vietnam | Brooks SLA5863 Thermal Mass Flow Meter |
| Model: SLA5863S3ABA0C2A1A5D1AA | ||
| (Model: SLA5863S3A0C2A1A5D1AA | ||
| SN : F13319-001 | ||
| Gas : CO2 | ||
| Flow rate : 0-40kg/h) | ||
| 100% USA Origin | Brooks Instrument Vietnam | Replaced by: 1250A-D6041 |
| Brooks Instrument Flowmeter | ||
| 1250 Glass Tube Flow meter | ||
| 1250A: Glass Tube Flow Meter With Horizontal Connections | ||
| Tube model: D6041 Glass float | ||
| Fluid Type: Air | ||
| Unit of measurement: CCM | ||
| End Block Material: Stainless Steel | ||
| Valve Designation: Needle Valve at inlet | ||
| O-ring material: Viton | ||
| Fitting: 1/4" NPT-F | ||
| Note: 1510 model is discontinued. Replacement model is 1250. But flow range is not exactly same. I quoted 20-900 ccm Air. Next higher is 50-1200 ccm | ||
| (Model: 1510 with meet the below specifications | ||
| Pressure: 300psig up to 250oF max | ||
| Material : Glass 316SS | ||
| Connections: 1/4"NPT | ||
| Type of Fluid: Gas. | ||
| Flow range: 100-1000ccm | ||
| Line valve inlet) | ||
| 100% USA Origin | Brooks Vietnam | 3809 Armored Flowmeter |
| 3809/E12D1BEAEAA | ||
| Note: | ||
| · We are assuming it is water for now. | ||
| Do find out the liquid density and viscosity and the flow range required. | ||
| · This model we quoted comes with 4-20mA output transmitter. | ||
| · We follow the code your sales engineer provided. | ||
| · If signal output is not required, please confirm then price is much lower. | ||
| (Model: 3809E12D1) | ||
| 100% USA Origin | Brooks Instrument Vietnam | 5850E Mass Flow Controller |
| Brooks Instrument | ||
| Model: 5850EC1BF3PB2A | ||
| S/N: 8611HCO23461/1. |