DRAIN MASTER B Operation Principle
1) Condensate that is flowed through lead-in line 1 is gathered to housing 2
2) If condensate water level rises in housing, it is sensed in the high level sensor 3.
3) Electric actuation ball valve 5 is run if transmit open signal in main board and condensate is
discharged through outlet 6
discharged through outlet 6
4) If level of condensate water inside housing comes down 4 it is sensed in the sensor bottom
dead center, and electric actuation 6 ball valve that received close signal is closed.
dead center, and electric actuation 6 ball valve that received close signal is closed.
Electrostatic Capacity Sensor
Any condensate from compression process can be sensed
correctly and discharged.
correctly and discharged.
Zero loss of compressed air.
Uses of two sensors (High level, low level) protects energy loss
By air loss discharging condensate selectively
By air loss discharging condensate selectively
Automatic discharge function[Alarm]
In case of condensate in not discharged while 2 min. by scale etc.,
It makes recognition to user through alarm signal and it is converted
to automatic restoration function and it activates electric motion
ball valve by 5 sec. every 3min. It is returned by normal mode if
discharge is activated normally.
It makes recognition to user through alarm signal and it is converted
to automatic restoration function and it activates electric motion
ball valve by 5 sec. every 3min. It is returned by normal mode if
discharge is activated normally.
Durability [Hard-Anodizing]
Housing coated rigid coating applying for aircraft, semiconductor
Equipment etc. of industrial equipment required durability is excellent
nature of rust proof durability and abrasion etc. so that life of housing is
Semi-permanent.
Equipment etc. of industrial equipment required durability is excellent
nature of rust proof durability and abrasion etc. so that life of housing is
Semi-permanent.
Various model, beautiful design
Extended user’s selection by subdividing into three models according
to quantity of condensate, and housing is processed by anodizing method
and die casting mold that has beautiful design
to quantity of condensate, and housing is processed by anodizing method
and die casting mold that has beautiful design
Convenience of install and maintenance
Put lead-in line more than 2 lines so that power connection is easy
and piping is convenient
and piping is convenient
Housing internal pollutant cleaning is simple
The built-in strainer can prevent blockage of valve by sludge
DRAIN
|
Peak
|
Peak
|
Peak
|
Operating
|
Temperature
| |||||||||||||||
Climate
|
Compressor
|
Dryer
|
Filter
|
Pressure
|
Application
| |||||||||||||||
MASTER S/HP
|
zone
|
Performance
|
Performance
|
Performance
|
min / max
|
min / max
|
( * )
| |||||||||||||
m3/min
|
m3/min
|
m3/min
|
(bar)
|
(℃)
| ||||||||||||||||
DM-5N
|
Green
|
8
|
16
|
80
| ||||||||||||||||
Blue
|
7
|
14
|
70
| |||||||||||||||||
Red
|
5
|
10
|
50
| |||||||||||||||||
DM-15
|
Green
|
24
|
48
|
240
| ||||||||||||||||
Blue
|
21
|
42
|
210
| |||||||||||||||||
Red
|
15
|
30
|
150
| |||||||||||||||||
DM-50
|
Green
|
80
|
160
|
800
| ||||||||||||||||
Blue
|
70
|
140
|
700
| |||||||||||||||||
Red
|
50
|
100
|
500
|
0.8~16
|
0~80
|
A.B
| ||||||||||||||
DM-150
|
Green
|
170
|
340
|
1700
| ||||||||||||||||
Blue
|
150
|
300
|
1500
| |||||||||||||||||
Red
|
105
|
210
|
1050
| |||||||||||||||||
DM-500
|
Green
|
570
|
1140
|
5700
| ||||||||||||||||
Blue
|
500
|
1000
|
5000
| |||||||||||||||||
Red
|
350
|
700
|
3500
| |||||||||||||||||
DM-1500
|
Green
|
1750
|
3500
| |||||||||||||||||
Blue
|
1500
|
3000
|
N/A
| |||||||||||||||||
Red
|
1050
|
2100
| ||||||||||||||||||
DM-15HP
|
Green
|
24
|
48
|
240
| ||||||||||||||||
Blue
|
21
|
42
|
210
| |||||||||||||||||
Red
|
15
|
30
|
150
| |||||||||||||||||
DM-50HP
|
Green
|
80
|
160
|
800
| ||||||||||||||||
Blue
|
70
|
140
|
700
|
1.2/60
|
+ 1 / 80
|
A.B
| ||||||||||||||
Red
|
50
|
100
|
500
| |||||||||||||||||
DM-150HP
|
Green
|
170
|
340
|
1700
| ||||||||||||||||
Blue
|
150
|
300
|
1500
| |||||||||||||||||
Red
|
105
|
210
|
1050
| |||||||||||||||||
*Application: A.oil contaminated condensate ; B.oil free, aggressive condensate
| ||||||||||||||||||||
DRAIN MASTER S/HP
|
DM-5N
|
DM-15
|
DM-50
|
DM-150
|
DM-500
|
DM-1500
|
DM-15HP
|
DM-50HP
|
DM-150HP
| |||||||||||
Condensate Feed
|
1/2" x 2
|
3/4" x 3
|
1"x1,3/4''x2
|
1/2" x 2
|
3/4" x 3
| |||||||||||||||
Condensate Discharge
|
3/8"
|
1/2"
|
3/8"
| |||||||||||||||||

Không có nhận xét nào:
Đăng nhận xét